ORT Controller & Transmitter
MODEL : ORT 601 - 1
Display : 4 + 4 Digit 0.5” & 0.39” 7 Seg RED LED Display
Electrode Input: Platinum Electrode with BNC Attachment
Relay Output: Relay - 1 for Setpoint - 1, Relay - 2 for Setpoint - 2 with 5A Rating
- Introduction
- Specifications
- Key Features
Product Details
The ORT 601 - 1 series of ORP Controller and Transmitter provides a reliable method of Monitoring, Controlling & Transmitting 4 - 20mA / RS 485 MODBUS RTU communication for interfacing to PLC, Data logger, HMI, etc.,. This product is suitable to measure ORP in water treatment, Electrolytic water cleaning, Chemical industries, Food process, Waste water treatment, Textile industries & Neutralization process, etc.,.
This ORP Controller & Transmitter can measured using Industrial platinum ORP sensor. This ORP Controller & Transmitter has many user friendly and safety features which as follows.
| Model | ORT 601-1 |
|---|---|
| Display | 4 + 4 Digit 0.5” & 0.39” 7 Seg RED LED Display |
| Range | -1999 to 1999 ORP |
| Accuracy | ± 1 ORP ± 1 digit |
| Resolution | 1 ORP |
| Electrode Input | Platinum Electrode with BNC Attachment |
| Set Point - 1 & 2 | Two Set Point with 6 relay status selectable |
| Relay Output | Relay - 1 for Setpoint - 1, Relay - 2 for Setpoint - 2 with 5A Rating |
| Relay Hysteresis | 0 to 5 ORP (user adjustable) (only for High & Low control modes) |
| Relay Cyclic delay | 0 to 100 seconds (user adjustable) (only for High & Low control modes) |
| Input Impedance | >10¹² Ohms |
| Alarm Output (optional) | Inbuilt audible buzzer with front key reset |
| Optional Re. Tx. output | Galvanically Isolated 4 - 20 mA |
| Optional Comm. output | Isolated RS 485 |
| Comm. Protocol | MODBUS RTU |
| Operating Environment | -10 to 50ºC / 10 to 95 % RH Non Condensing |
| Power Supply | 90 to 270V AC / DC 50Hz |
| Dimension | 96 x 96 x 85 mm |
| Cutout Dimension | 92 x 92 mm |
| Weight | 350 grams (Approx.) |
Note: Due to continuous product improvements, Published specifications may change with out notice
Economical, easy to calibrate and setup
Wide range from -1999 to 1999 ORP
High Accuracy
Optional isolated RS 485 communication with MODBUS RTU protocol
Optional galvanically isolated 4 – 20mA output
Very high output impedance >10¹² Ohms
User selectable single or 2 point calibration
2 relay outputs with configurable individual H/L setting with 6 relay status
Optional audible inbuilt buzzer output with front key reset
Universal supply voltage 90 to 270V AC/DC