Dry Block Temperature Calibrator
Model : TCAL 1501 / 600
Temperature Range: ±5°C to 600°C
- Introduction
- Specifications
- Key Features
- Software Optional
- Accessories
Product Details
SANSEL Model TCAL 1501 series of Dry well Temperature calibrator range from -35 to 1200°C in four model
(TCAL 1501 / -35, TCAL 1501 / 300, TCAL 1501 / 600 & TCAL 1501 / 1200) are high precision, better resolution,
stability, fast in heating and cooling. More well dia and depth to calibrate more number of temperature
sensor at a time with better uniformity.
These models can meet any calibration requirement in laboratories or in on site applications. This models are
inbuilt measuring facility of the Thermocouples, RTD, Resistance, millivolt & milliamps to directly read the
signals from most of the temperature sensors, indicator with sensor and Transmitter. Temperature range
from Amb.+ 5°C to 600°C with high resolution 0.01°C up to 600°C. This model is mainly used in all industries,
like Pharmaceutical, food, Research & calibration laboratories etc.,.
These models are using 4.3” True colour TFT display with Touch screen, easy to read multi parameter at the
same time like, Block temperature, set temperature, measure value, Real time clock with date & time,
Control Output %, Stability time & status, Range of the equipment with necessary unit of measurement and
three soft touch keys are used for measure configuration, settings, calibration etc.., It has one more
advantage of help menu for operating instruction of the equipment via the same screen , Hence no need of
Hard copy of Instruction manual.
| Model | TCAL 1501 / 600 |
|---|---|
| Display | 4.3 inch True TFT display with touch screen |
| Temperature Range | Amb. +5 to 600°C |
| Resolution | 0.01°C |
| Stability | ± 0.05°C |
| Radial Uniformity | Better than ± 0.5°C |
| Measure Inputs | RTD-PT 100, PT 1000 / TC - J, K, R, S, T, E, B, N / mA, mV, ohms |
| Temperature Readout | °C |
| Stabilization Time | 15 minutes |
| Heating Time | 30 mins (25 to 600°C) |
| Cooling Time | 50 mins (600 to 100°C) |
| Well Dimension | 30 × 150 mm (dia × height) |
| Test Sensor Immersion Depth | 140 mm |
| Standard Well Holes in mm | 5.1, 6.2, 6.2 & 8.1 |
| PC Interface (optional) | RS 232 with automatic calibration software |
| UUC Sensor Supply Output | 24V DC ± 10% / 50mA max. |
| Power Supply | 230V AC ± 10% / 50Hz (optional 110V AC) |
| Power Consumption | 1200 VA |
| Switch Test | Provided |
| Overall Dimension in mm | 285 × 155 × 330 (L × B × H) (Approx.) |
| Weight | 8.5 kg (without well insert) (Approx.) |
Note: Due to continuous product improvements, Published specifications may change without notice.
4.3 inch True TFT DISPLAY with touch screen
Portable & Rugged
Range from Amb. + 5 to 600 °C
Resolution 0.01 °C
Stability ±0.05°C
Radial Uniformity ±0.5°C
UUC measure option provided
Stabilization time & status indication provided
Inter changeable insert to suit different diameter sensor -up to 30 mm
Optional PC Interface with automatic calibration software
Optional fully automatic documentation calibration software “SANSELSOFT” is provided with TCAL 1501 / 600 to calibrate different variety of UUC automatically from your PC or Laptop and generate the calibration report with exact results without your presence always near TCAL 1501 / 600 , will save your time to concentrate in various jobs. The SANSELSOFT calibration software having easy following steps makes your calibration easy , effective & time saver.
- Step1: Create tag of Device / Unit under calibration (DUC/ UUC)
Select tag of Device / Unit under calibration (DUC/ UUC) (if already tag created) - Step2: Specify calibration procedure
- Step3: Select source of calibrator
Select measurement calibrator (If different measurement equipment available) - Step4: Select mode of calibrator
Select mode of measurement (If different measurement equipment available) - Step5: Perform calibration
- Step6: Specify Report number, Conclusion & Remarks
- Step7: Print / Export Report
SANSELSOFT designed for perform calibration on field instruments with the use of standards and software communication. This software designed in the way, user can easily perform calibration. SANSELSOFT has powerful database support to maintain complete track records of each device calibration for long time. SANSELSOFT supports communication interface standards RS 232 and provides facility to add new standard/DUC instrument library. SANSELSOFT can be adopted for various types of instruments like electronic, electrical, temperature, pressure and optical measurement devices. SANSELSOFT increases Standard's Life-time by eliminating key operations and saves maintenance cost.
Standard Accessories
- Basic Instruments
- Instruction Manual
- Mains Card
- Spare Fuses
- Well Tool
- Standard well insert – 1 nos
Optional Accessories
- Master Indicator with sensor
- Additional well insert
- Carrying case
- ISO/IEC 17025 Accredited calibration certificate