Temperature Calibrator

Product Image

High Precision Very Low Temperature Dry Block Calibrator

Model: TCAL 1503 / -40

Temperature Range:-40 to 120°C

High efficiency, Fast cooling & Heating, Energy saving & Fluid free.

Product Details

Sansel model TCAL 1503/-40 Metrology Grade Very Low Temperature Dry Block Calibrator incorporate Solid-state, Heating and Cooling Technology. This dry well has an advantage of wide temperature range from -40 to 120°C, CFC Free, high efficiency, Fast cooling & Heating, Energy saving & Fluid free. Hence it is a great alternative to Fluidized bath and best suitable for clean room environment.

This Portable Dry Block Calibrator is a high precision, more resolution, better stability, Uniformity, big well dia and depth to calibrate more number of temperature sensors at a time. This model can meet any calibration requirement in laboratories or in Onsite applications. It has inbuilt measuring facility of thermocouples, RTD, Resistance, millivolts, Volts, ohms & milliamps to directly read the signals from most of the temperature sensors, indicator with sensors and transmitters.

This Dry well calibrator model is using 4.3” True colour display with touch screen, easy to read multi parameter at the same time like, Block temperature, Set temperature, Measure value, real time clock with date & time , Control output %, Stability time & Status, Range of the equipment with necessary unit of measurement and three Touch panel keys are used for measure Configuration, Settings, Calibration etc.,. It has one more advantage of help menu for operating instruction of the equipment via the same display screen, Hence no need of hard copy of Instruction manual.

Model TCAL 1503/-40
Display 4.3 inch True TFT Display with Touch screen
Temperature Readout °C / °F (Selectable)
Temperature Range -40 to 120°C @23°C Ambient
Resolution 0.01°C
Block Stability Better than ± 0.03°C at full range
Block Radial Uniformity ± 0.02°C at full range
Block Axial uniformity
(upto 40 mm )
± 0.18°C at -40°C
± 0.1°C at 0°C
± 0.05°C at 50°C
± 0.11°C at 100°C
± 0.17°C at 120°C
Loading effect Better than ± 0.08°C
hysteresis Better than ± 0.03°C
Heating Time 25 mins (25 to 120 °C)
75 mins (-40 to 120 °C)
52 mins (-40 to 25 °C)
Cooling Time 30 mins (25 to -40 °C)
15 mins (25 to -30 °C)
65 mins (120 to 25 °C)
Stabilization Time 10 min
Insert (Dia. x Height) 30 X 160 mm
Test sensor immersion depth 155 mm
Standard well holes in mm Insert No. 1 → 5.1, 6.2, 6.2 & 8.1, Insert No. 2 → 6.2, 6.2 & 10.2
Measure inputs RTD-PT 100, PT 1000 / TC - J, K, R, S, T, E, B , N , Analog – mA, V, mV, ohms
Cold junction Accuracy ± 0.3°C
UUC Sensor supply input 24V DC ± 10% / 50mA max.
Note: Due to continuous product improvements, Published specifications may change with out notice
  • 4.3” true colour TFT display with touch screen
  • Wide temperature range from -40 to 120°C
  • Resolution 0.01°C
  • Metrology level performance
  • Improved radial & axial uniformity up to 40mm height
  • Meet the EURAMET Cg-13 requirement
  • Stabilization time & status indication provided
  • Fast heating & cooling
  • Quick settling , Portable & Rugged
  • Solid state heating and cooling technology
  • Interchangeable 30mm dia x 150mm length insert to suit different diameter of sensor
  • Inbuilt DUC measurement facility RTD, TC, mV, V, mA & ohms
  • Light weight – less than 16kg
  • Easy onsite carriable
  • Low power consumption – less than 500W
  • ISO/IEC 17025 Accredited calibration certificate
  • Optional PC Interface with automatic calibration software

Optional fully automatic documentation calibration software “SANSELSOFT” is provided with TCAL 1503 / -40 to calibrate different variety of UUC automatically from your PC or Laptop and generate the calibration report with exact results without your presence always near TCAL 1503 / -40 , will save your time to concentrate in various jobs. The SANSELSOFT calibration software having easy following steps makes your calibration easy , effective & time saver.

  • Step1: Create tag of Device / Unit under calibration (DUC/ UUC)
    Select tag of Device / Unit under calibration (DUC/ UUC) (if already tag created)
  • Step2: Specify calibration procedure
  • Step3: Select source of calibrator
    Select measurement calibrator (If different measurement equipment available)
  • Step4: Select mode of calibration
    Select mode of Measurement (if different measurement equipment available)
  • Step5: Initialize source / Measurement Calibrators
  • Step6: Perform calibration
  • Step7: Specify Report number, Conclusion & Remarks
  • Step8: Print / Export Report

SANSELSOFT designed for perform calibration on field instruments with the use of standards and software communication. This software designed in the way, user can easily perform calibration. SANSELSOFT has powerful database support to maintain complete track records of each device calibration for long time. SANSELSOFT supports communication interface standards RS 232 or USB and provides facility to add new standard/DUC instrument library. SANSELSOFT can be adopted for various types of instruments like electronic, electrical, temperature, pressure and optical measurement devices. SANSELSOFT increases Standard's Life-time by eliminating key operations and saves maintenance cost.

Standard Accessories
  • Basic Instruments
  • Spares fuses
  • Standard well insert – 2nos
  • Instruction Manual
  • Well tool
  • Mains card
Optional Accessories
  • Master indicator with sensor
  • Additional well insert
  • ISO/IEC 17025 Accredited calibration certificate
  • Carrying case