Liquid Temperature Calibration Bath
MODEL : TCAL 1501 / 250
Temperature Range:Amb. +5 to 250 °C
Large volume testing area 60mm Dia x 120mm
High Resolution0.01 °C up to 250 °C
4.3” True colour TFT display with Touch screen, easy to read multi parameter at the same time like, Block temperature.
- Introduction
- Specifications
- Key Features
- Calibration software (optional)
- Accessories
Product Details
SANSEL Model TCAL 1501/250 of Liquid Temperature calibration bath range from Amb. +5 to 250 °C are high precision, better resolution, stability, fast in heating and cooling. Large volume testing area 60mm Dia x 120mm Depth to calibrate more number of Thermometer at a time with better uniformity using Magnetized stirring. These models can meet any calibration requirement in laboratories or in on site applications. This models are inbuilt measuring facility of the Thermocouples, RTD, Resistance, millivolt & milliamps to directly read the signals from most of the temperature sensors, indicator with sensor and Transmitter.
Temperature range from Amb. +5 to 250 °C with high resolution 0.01 °C up to 250 °C. This model is mainly used in all industries, like Pharmaceutical, food, Research & calibration laboratories etc., These models are using 4.3” True colour TFT display with Touch screen, easy to read multi parameter at the same time like, Block temperature, set temperature, measure value, Real time clock with date & time, Control Output %, Stability time & status, Range of the equipment with necessary unit of measurement and three soft touch keys are used for measure configuration, settings, calibration etc.., It has one more advantage of help menu for operating instruction of the equipment via the same screen , Hence no need of Hard copy of Instruction manual.
| Model | TCAL 1501/ 250 |
|---|---|
| Temperature Range | Amb. +5 to 250°C |
| Resolution | 0.01°C |
| Stability | ±0.03 °C |
| Accuracy | Better than ± 0.3°C |
| Radial Uniformity | Better than ± 0.15°C |
| Display | 4.3 inch True TFT display with touch screen |
| Stabilization Time | 45 minutes |
| Heating time | 60 mins (Amb. to 250°C) |
| Cooling time | 90 mins (250 to 50°C ) |
| Chamber Dimension | 80 x 140 mm (dia X depth) |
| Testing area | 60 x 120 mm (dia X depth) |
| Temperature medium | Silicon oil (200cs recommended) |
| Measure inputs | RTD-PT 100, PT 1000 / TC-J, K, R, S, T, E, B , N / mA /mV / ohms |
| PC Interface | RS 232 (optional) |
| Power supply | 230V AC or 110V AC 50/60Hz |
| Power consumption | 1200 VA |
| Switch test | Provided |
| Dimension in mm | 340 x 175 x 425 (L x W x H) (Approx.) |
| Weight (Approx.) | 12 kg (without liquid) |
Note: Due to continuous product improvements, Published specifications may change with out notice
4.3 inch True TFT display with touch screen
Portable & Rugged
Range from Amb. + 5 to 250 °C
Resolution 0.01 °C
Stability ± 0.03°C
Uniformity better than ± 0.15°C
UUC measure option provided
Stabilization time & status indication provided
Inter changeable insert to suit different diametersensor - up to 60 mm
Optional PC Interface with automatic calibration software
Optional fully automatic documentation calibration software “SANSELSOFT” is provided with TCAL 1501 / 250 to calibrate different variety of UUC automatically from your PC or Laptop and generate the calibration report with exact results without your presence always near TCAL 1501 / 250 , will save your time to concentrate in various jobs. The SANSELSOFT calibration software having easy following steps makes your calibration easy , effective & time saver.
- Step1: Create tag of Device / Unit under calibration (DUC/ UUC)
Select tag of Device / Unit under calibration (DUC/ UUC) (if already tag created) - Step2: Create / Specify calibration procedure
- Step3: Select source of calibrator
Select measurement calibrator (If different measurement equipment available) - Step4: Initialize source / Measurements calibrators
- Step5: Perform calibration
- Step6: Specify Report number, Conclusion & Remarks
- Step7: Print / Export Report
SANSELSOFT designed for perform calibration on field instruments with the use of standards and software communication. This software designed in the way, user can easily perform calibration. SANSELSOFT has powerful database support to maintain complete track records of each device calibration for long time.
SANSELSOFT supports communication interface standards RS 232 and provides facility to add new standard/DUC instrument library. SANSELSOFT can be adopted for various types of instruments like electronic, electrical, temperature, pressure and optical measurement devices. SANSELSOFT increases Standard's Life-time by eliminating key operations and saves maintenance cost.
Standard Accessories
- 1.Basic Instrument
- 2.Cable for Thermostat Switch Test
- 3.Cable for Thermocouple (TC) test probe
- 4.Cable for RTD test probe
- 5.Aluminium Dummy cover
- 6.Teflon top cover
- 7.Thermometer stand set
- 8.Silicon oil - 1 liters
- 9.SS insert bucket
- 10.Stir magnet (2 nos)
- 11.Instruction Manual
- 12.Traceable Calibration Certificate
- 13.Mains Card
- 14. Spare Fuses
Optional Accessories
- 1.Master Indicator with sensor
- 2.ISO/IEC 17025 Accredited calibration certificate
- 3.Additional well insert
- 4.Carrying case