- Home
- / TDS 602 – 1 (TDS Indicator/Controller)
TDS Controller & Transmitter
TDS 602 – 1
The TDS 602 - 1 series of TDS Controller and Transmitter provides a reliable method of Monitoring, Controlling & Transmitting 4 - 20mA / RS 485 MODBUS RTU Communication for Interfacing to PLC & Data logger. This product is suitable to measure TDS in water treatment, Electrolytic water cleaning, Chemical Industries, Food Process, Waste Water treatment, Textile Industries & Neutralization process, etc.,.
This TDS Controller & Transmitter can Measured using Industrial TDS Sensors, Temperature can be measured using temperature sensor. This TDS Controller & Transmitter has many user friendly and safety features which as follows.
- Economical, Easy to Calibrate and Setup
- User selectable 6 ranges from 1ppm to 200ppt
- High Accuracy
- Programmable Auto / Manual Temperature Compensation
- Optional Isolated RS 485 communication with MODBUS RTU protocol
- Optional Galvanically Isolated 4-20mA Re Trans. Output
- Adjustable Cell Constant for particular ranges
- Manual single or 2 point Calibration
- 2 Relay Outputs with Configurable individual H/L Setting with 6 relay status
- Optional audible inbuilt buzzer Output with Front key reset
- Universal Supply Voltage 90 to 270V AC / DC
- Model : TDS 602 - 1
- Display : 4 + 4 Digit 0.5” & 0.39” 7 Seg RED LED Display
- Cell Constant : * 0.01 / 0.1 / 1(user selectable depends on range*)
- Range(any one) 1 - 20ppm, 5 - 200ppm, 10 to 2000ppm, 1 to 20ppt, 5 to 200ppt
- Resolution : 0.01ppm to 0.1ppt (depends on range)
- Temp. Compensation Manual / Automatic (-20.0 to +150.0ºC)
- Temp. Sensor : RTD - PT 100 (3 wire)
Temp. Coefficient : 0 to 3 % / ºC(user adjustable)
Electrode Input Conductivity cell on rear panel
Accuracy : ± 1 % of range ± 1 digit
Set Point - 1 & 2 Two Set Point with 6 Relay Status Selectable
Relay Output : Relay - 1 for Setpoint - 1, Relay - 2 for Setpoint - 2 with 5A Rating
Relay Hysterisis : 0 to 500 counts (user adjustable)(only for High & Low control modes)
Relay Cyclic delay : 0 to 100 seconds (user adjustable)(only for High & Low control modes)
Alarm Output(optional) inbuilt audible buzzer with front key reset
Optional Re. Tx. output Galvanically Isolated 4 - 20 mA
Optional Comm. output Isolated RS 485
Comm. Protocol MODBUS RTU
Operating Environment -10 to 50ºC / 10 to 95 % RH Non Condensing
Power Supply : 90 to 270V AC / DC 50Hz
- Enclosure: ABS Plastics
Dimension : 96 x 96 x 85 mm.
Cutout Dimension 92 x 92 mm
Weight : 500 grams (Approx.)
- Basic Instrument
- Panel mount Clamp set
- Instruction manual
Optional
- Combined Electrode with PP adapter for easy pipe line fitting
4 & 7 pH standard tablet with container
Imported certified Standard buffer Solution
Pipe line Flow Through assembly
“L” type PVC setup for electrode for Tank installation