Dry Block Temperature Calibrators
Dry Block Temperature Calibrators

HTP 196

Measurement of relevant climatic data is becoming more and more important in Clean room , Storage, Manufacturing, Testing and Calibration lab, Research lab etc,. This Humidity, Temperature & Pressure indicator offer very accurate measurement of Relative Humidity, Temperature and Absolute pressure (or) differential pressure by excellent readability of very high intensity seven segment LED display.The Humidity ,Temperature & Pressure indicator housed with rugged case allow to use in tough industrial environments, Latest technology and well proven sensor guaranteed high accuracy and long term stable measurement.

  • High intensity , 7 segment LED display for long distance viewing
  • Pre selectable ( Low & High ) alarm output for all three parameter
  • Two relay with one buzzer output
  • Easy wall mountable with key hole provision.

? Compact in size and rugged use , etc,.

Measurement of relevant climatic data is becoming more and more important in Clean room , Storage, Manufacturing, Testing and Calibration lab, Research lab etc,. This Humidity, Temperature & Pressure indicator offer very accurate measurement of Relative Humidity, Temperature and Absolute pressure (or) differential pressure by excellent readability of very high intensity seven segment LED display.The Humidity ,Temperature & Pressure indicator housed with rugged case allow to use in tough industrial environments, Latest technology and well proven sensor guaranteed high accuracy and long term stable measurement.

  • High intensity , 7 segment LED display for long distance viewing
  • Pre selectable ( Low & High ) alarm output for all three parameter
  • Two relay with one buzzer output
  • Easy wall mountable with key hole provision.

? Compact in size and rugged use , etc,.

  • Model : HTP-196
  • Display : 3 line 4digit ,0.5” 7 segment LED
  • Parameter : T e mp, Humidity & Absolute or differential (pressure)
  • Range : 0 to 60°C / 0to100%RH/ 0 to 2000mbarA or ±50pa
  • Resolution : 0.01°C / 0.1%RH / 1mbar A (or) 0.01pa
  • Set point : Low & High for all three parameter
  • Relay : 2 relay with 5A rating with selectable parameter
  • Sensor : P T-100, Humidity & Pressure sensor with 2m cable
  • Operating Environment : 0 to 5 0 ° C / 20 to 95 %RH Non cond e n s i n g
  • Supply : 9 0 to 270V AC / 50Hz
  • Dimension : 100 mm W x 250 mm H x60 mm D
  • Mounting : W a ll mountable with key hole provision
  • Buzzer : Inbuilt
  • Weight : 640gms