- Home
- / TCAL 1503/-45
TCAL 1503/-45
SANSEL Model TCAL 1503 series of Dry well Temperature calibrator range from -45 to 1200 °C in four model (TCAL 1503 / -45, TCAL 1503 / -35, TCAL 1503 / 300, TCAL 1503 / 600 & TCAL 1503 / 1200) are high precision, better resolution, stability, fast in heating and cooling. More well dia and depth to calibrate more number of temperature sensor at a time with better uniformity. These models can meet any calibration requirement in laboratories or in on site applications. This models are inbuilt measuring facility of the Thermocouples, RTD, Resistance, millivolt & milliamps to directly read the signals from most of the temperature sensors, indicator with sensor and Transmitter. Temperature range from -45 to 130 °C with high resolution 0.01 °C up to 130 °C. This model is mainly used in all industries, like Pharmaceutical, food, Research & calibration laboratories etc., These models are using 4.3” True colour TFT display with Touch screen, easy to read multi parameter at the same time like, Block temperature, set temperature, measure value, Real time clock with date & time, Control Output %, Stability time & status, Range of the equipment with necessary unit of measurement and three soft touch keys are used for measure configuration, settings, calibration etc.., It has one more advantage of help menu for operating instruction of the equipment via the same screen , Hence no need of Hard copy of Instruction manual.
4.3 inch True TFT DISPLAY with touch screen
Portable & Rugged
Range from -45* to 130 °C
Resolution 0.01 °C
Stability ± 0.02°C
Radial Uniformity better than ± 0.02°C
Axial Uniformity upto 40mm better than ± 0.2°C
UUC measure option provided
Stabilization time & status indication provided
Inter changeable insert to suit different diameter sensor - up to 30 mm
Optional PC Interface with automatic calibration software
- Model : TCAL 1503 / -45
- Temperature Range : -45* to 130 °C * @ 23 °C Ambient
- Resolution : 0.01 °C
- Stability : ± 0.02 °C
- Radial Uniformity : Better than ± 0.02 °C
- Axial Uniformity (40mm) :
± 0.1 °C at -45 °C
± 0.1 °C at -30 °C
± 0.05 °C at 0 °C
± 0.05 °C at 100 °C
± 0.2 °C at 130 °C
- Display : 4.3”
± 0.1 °C at -45 °C
± 0.1 °C at -30 °C
± 0.05 °C at 0 °C
± 0.05 °C at 100 °C
± 0.2 °C at 130 °C
- Temperature Read out : °C / °F (selectable)
- Cooling time :
30 mins (25 to -45 °C)
15 mins (25 to -30 °C)
65 mins (130 to 25 °C)
- Heating time :
25 mins (25 to 130 °C)
75 mins (-45 to 130 °C)
52 mins (-45 to 25 °C)
- Stabilization time : 10 minutes
- Well Dimension(dia. x height) : 30 x 160 mm
- Test sensor immersion depth : 130 mm
- Standard well holes in mm : Insert No. 1 5.1, 6.2, 6.2 & 8.1, Insert No. 2 6.2, 6.2 & 10.2
- Measure inputs : RTD – PT 100, PT 1000, TC – J, K, R, S, T, E, B, N , Analog – mA, mV, Ohms
- Switch Test : Provided
- UUC sensor supply output : 24V DC ± 10% / 50mA max.
- Power supply : 230V AC ± 10% / 50Hz (Optional 110V AC)
- Power Consumption : 500 VA
- Overall Dimension in mm : 390 x 185 x 356 (L x B x H)(Approx.)
- Instrument Weight : 16.6 kg(with well insert)(Approx.)
1.Basic Instrument
2.Spare fuses
3.Standard well insert – 2nos
4.Well tool
5.Instruction manual
6.Mains card
7.Traceable calibration certificate
Optional
1.Master Indicator with sensor
2.Additional well insert
3.Carrying case