Dry Block Temperature Calibrators
Dry Block Temperature Calibrators

SANSEL Model TCAL 1501/250 of Liquid Temperature calibration bath range from Amb. +5 to 250 °C are high precision, better resolution, stability, fast in heating and cooling. Large volume testing area 60mm Dia x 120mm Depth to calibrate more number of Thermometer at a time with better uniformity using Magnetized stirring. These models can meet any calibration requirement in laboratories or in on site applications. This models are inbuilt measuring facility of the Thermocouples, RTD, Resistance, millivolt & milliamps to directly read the signals from most of the temperature sensors, indicator with sensor and Transmitter.

Temperature range from Amb. +5 to 250 °C with high resolution 0.01 °C up to 250 °C. This model is mainly used in all industries, like Pharmaceutical, food, Research & calibration laboratories etc., These models are using 4.3” True colour TFT display with Touch screen, easy to read multi parameter at the same time like, Block temperature, set temperature, measure value, Real time clock with date & time, Control Output %, Stability time & status, Range of the equipment with necessary unit of measurement and three soft touch keys are used for measure configuration, settings, calibration etc.., It has one more advantage of help menu for operating instruction of the equipment via the same screen , Hence no need of Hard copy of Instruction manual.

  • 4.3 inch True TFT DISPLAY with touch screen
  • Portable & Rugged
  • Range from Amb. + 5 to 250 °C
  • Resolution 0.01 °C
  • Stability ± 0.03°C
  • Radial Uniformity better than ± 0.02°C
  • UUC measure option provided
  • Stabilization time & status indication provided
  • Inter changeable insert to suit different diameter sensor - up to 60 mm
  • Optional PC Interface with automatic calibration software
  • Model: Tcal 1501 / 250
  • Display: 4.3 inch true TFT display with touch screen
  • Temperature Range: +5 to 250 °C
  • Resolution: 0.01 °C
  • Stability: ± 0.03 °C
  • Accuracy: better than ± 0.3 °C
  • Stabilization Time: 45 minutes
  • Heating Time: 60 mins ( Amb. to 250°C
  • Cooling Time:
    60 mins ( Amb. to 250°C
  • Chamber Dimension: 80 x 140 mm (dia depth)
  • Testing Area: 60 x 120 mm (dia X depth)
  • Temperature Medium: Silicon Oil (200cs recommended)
  • Measure inputs : RTD-PT 50,PT 100,PT500,PT1000 / TC -J, K, R,S,T,E,B,N/mA/mV/ ohms
  • Multi Hole Well: Provided for Different Types of Sensors
  • Dimension in mm: 340 x 175 x 425 (L* W * H) (Approx.)
  • Power Supply: 230V AC ± 10% / 50Hz (Optional 110V AC)

Due to continuous product improvements, Published specifications may change with out notice

Standard Delivery

Basic Instrument
Mains Card
Instruction Manual

Optional

Master Tachometer
Additional Reflection stickers
Carrying case