Dry Block Temperature Calibrators
Dry Block Temperature Calibrators

SANSEL offers PI 542A Model PROCESS INDICATORs are extremely versatile Indicators that can be used for a wide variety of applications. These INSTRUMENT offer extreme reliability and low cost for Process measurement and logging. PI 542A is a Microprocessor based instrumentation ensures accurate readings for all Linear Parameters. A number of programmable features including In-line calibration are standard. All the parameters are saved in a non volatile EEPROM memory which doesn't needs any external battery.

 

PI 542A can offer relay outputs for signals exceeding set points. Programmable Re Transmission output models are also available in addition to the industry standard 4 -20mA or 0 - 10V DC output. Optional RS 485 (2 wire ) output also provided for PC communication with PC Interface software & also with MODBUS RTU protocol.

Monitoring , Recording, Controlling process in various Applications as follows

Temperature
Humidity
Pressure
pH / ORP
TDS / Conductivity
Flow
Pressure
Level
Voltage / Current /Power
Resistance and More

4 Digit 7 segment RED LED display
High Accuracy
Compact Size
24 Bit ADC Resolution
Selectable Inputs RTD , all types of thermocouples , mA,
mV , Voltage , ohms
Wide Selectable Range between -1999 to 9999 counts
Easy Field Configurable with Front Key Calibration
No Hardware Selection For the Input Signals
Optional Opto Isolated Re Transmission Output.
Optional RS 485 (2 wire) Output for PC communicatio
Optional PC software with Monitoring, Logging, Report &
Graph
Optional MODBUS RTU protocol
24V DC External Sensor Supply
Programmable Decimal Point & Display Noise Filter
Universal Supply Voltage 90 to 270 AC / DC

Model: PI 542A
Display: 4 Digit 7 segment RED LED
Analog Inputs: 0 - 20 mA, 0 to 75 mV, -10 to 10 V DC, 0 - 400 Ù (H & L Limit Programmable)
Temperature Inputs: RTD - PT 100, Thermocouple - J, K, R, S, T, B, N, E
Analog Display Rang: - 1999 to 9999 (H & L Limit Programmable)
Temperature Range (H & L Limit Programmable: RTD - PT 100 (-199.9 to 850.0°C / -199.9 to 1562°F)
Unit selection: °C / °F (for RTD & TC inputs)
Analog Resolution: 0.001 / 0.01 / 0.1 / 1 (Selectable)
Temperature Resolution: 0.01(for RTD-PT 100 input(°C) only) / 0.1 / 1 °C / °F
Accuracy: ± 0.1 % of FS
Filter Constant: 1 - 100 % (Adjustable)
Sensor Supply(external): 24 V DC ±10% @ 100 mA
Operating Environment: 0 - 50ºC / 5 to 95 % RH Non Condensing
Power Supply: 90 to 270 V AC / DC / 50 / 60 Hz
Over All Dimension: 48(H) X 96(W) X 110(D) mm
Cut out Dimension: 44(H) X 90(W) mm

Due to continuous product improvements, Published specifications may change with out notice

stability of analog input depends on display high range counts

± 10 counts(± 2 lakhs counts), ± 8 counts(± 1 lakhs counts), ± 6 counts(± 50,000 counts), ± 2 counts(± 25,000 counts)

Relay & Retransmission or PC communication any one was possible in one PI 542A